7 steps · 2 traps to avoid · Whirlpool WP2315539 & WPW10392132 · Top-freezer WRT models
When the freezer of a Whirlpool top-freezer stays cold and the fresh-food section warms up, three faults are worth checking before anyone touches the refrigerant: dust on the condenser coils, an iced or worn evaporator fan, and a defrost fault that buries the evaporator in ice. See where each sits on the WRT519SZDM00 (the WRT318FZD’s cabinet) in 3D, and the two traps that ruin the panel or the coil, before you pick up a 1/4-inch nut driver.
A Whirlpool top-freezer whose freezer stays cold while the fresh-food section warms up can have one of three faults that are reached without opening the sealed refrigerant system: dusty condenser coils behind the base grille, an iced or worn evaporator fan behind the freezer’s rear panel, or a defrost fault that lets ice bury the evaporator coil. The 3D cuts the WRT519SZDM00 (the same cabinet as the WRT318FZD) into two sections on the bench: the freezer’s back wall on its stands, and the front of the machine compartment below it.
Tools: 1/4-inch nut driver, Condenser coil brush, Vacuum with a soft brush tool, Plastic spatula